  • The Milwaukee MC110 PRO is a professional bench-top monitor designed for continuous pH measurement in solutions.
  • It provides accurate readings across the full 0.0–14.0 pH range and is engineered for applications where constant monitoring is essential.
Producer: Milwaukee
146,01 €
/ piece
118,71 €
/ piece

Milwaukee MC110 PRO pH Monitor – professional monitor designed for continuous pH measurement in solutions

The Milwaukee MC110 PRO is a professional bench-top monitor designed for continuous pH measurement in solutions. It provides accurate readings across the full 0.0–14.0 pH range and is engineered for applications where constant monitoring is essential – from hydroponics and aquaculture to laboratories, food industry, and research facilities.

The device features an adjustable setpoint and a visual alarm that activates whenever the measured value exceeds the user-defined range. This ensures immediate alerts when conditions drift out of specification. The unit comes with the professional MA911B/2 pH electrode, delivering stable and repeatable measurements.

Its compact design, intuitive operation, and durability in demanding environments make the MC110 PRO a reliable tool for both professional users and hobbyists seeking precision and consistency.

Key Features

  • Wide measurement range: 0.0 – 14.0 pH

  • High accuracy: resolution 0.1 pH, ±0.2 pH (@25 °C)

  • Adjustable setpoint: 3.5 – 7.5 pH

  • Visual LED alarm when values exceed limits

  • Professional MA911B/2 electrode included with 2 m cable

  • Required calibration solutions: pH 7.01 and pH 4.01 (sold separately)

  • External 12 VDC power supply for stable performance

  • Robust design for environments 0–50 °C, up to 95% RH

  • Compact size: 148.5 × 82.5 × 32 mm, only 160 g

  • Easy calibration and quick readings on a clear display

  • Warranty: 2 years on the meter, 6 months on the electrode

For proper calibration, buffer solutions pH 7.01 and pH 4.01 are required (sold separately). Regular calibration is recommended to maintain maximum accuracy.

Technical Specifications

ParameterValue
Measurement range0.0 – 14.0 pH
Resolution0.1 pH
Accuracy (@25 °C)±0.2 pH
Setpoint range3.5 – 7.5 pH
AlarmVisual LED, above/below setpoint
ElectrodeMA911B/2 (included)
Electrode cable length2 m
Operating environment0 – 50 °C, up to 95% RH (non-condensing)
Power supply12 VDC adapter (included)
Dimensions148.5 × 82.5 × 32 mm
Weight160 g

 

Milwaukee PRO pH Probe Care 

pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

Sensing bulb

The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

Reference junction

The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

You can extend the life of your pH electrode in the following ways.

Storage

The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.

This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

Cleaning

Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.

Entity responsible for this product in the EU
Milwaukee Electronics Kft.More
ProducerMilwaukee Electronics Kft.Address: Alsó-Kikötő sor 11 C.Postal code: 6726City: SzegedCountry: WęgryE-mail: tech@milwaukeeinst.com
Responsible entityMilwaukee Electronics Kft.Address: Alsó-Kikötő sor 11 C.Postal code: 6726City: SzegedCountry: WęgryE-mail: tech@milwaukeeinst.com
Producer code
5999567670236
PH meter type
Electronic stationary for water
To download
Ask for this product

If this description is not sufficient, please send us a question to this product. We will reply as soon as possible.

Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.

Fields marked with an asterisk are required
Write your opinion
Your opinion:
5/5
Add your own product photo:
Zamknij
This page uses cookie files to provide its services in accordance to Cookies Usage Policy. You can determine conditions of storing or access to cookie files in your web browser.
Close
pixel